Wet underfloor heating systems are made of cross-linked polyethylene that is formed into tubes (pipe). These tubes are predominantly used in building services pipework systems, heating systems, domestic water piping and insulation for high tension (high voltage) electrical cables.

They are used in almost all water based underfloor heating systems because of their durabilty and efficiency.  Here at Underfloor Heat Store we have chosen the Pex-al-Pex piping because it is the best.  

Our Pex-al-Pex piping comes in various diameters ranging from 12mm to 32mm and comes in various lengths.

Filter
Price
View as Grid List

9 Items

Set Descending Direction
Clip Rails – 1 Metre
In-Stock

£1.20 Inc. VAT

Clip Rails – 1 Metre
60mm Pipe Clips (100)
In-Stock

£4.80 Inc. VAT

60mm Pipe Clips (100)
Aluminium Triple Spreader Plate
In-Stock
12mm Multi-layer Pipe (80m)
In-Stock
16mm Multi-layer Pipe (100m)
In-Stock
16mm Multi-layer Pipe (200m)
In-Stock
16mm Multi-layer Pipe (300m)
In-Stock
16mm Multi-layer Pipe (400m)
In-Stock
16mm Multi-layer Pipe (500m)
In-Stock
View as Grid List

9 Items

Set Descending Direction

Frequently Asked Questions

Could the piping burst under my floor?

This is highly unlikely when using quality underfloor heating pipes such as our Pex-al-Pex pipe as they are specially made for underfloor heating systems and also there are no joints within the floor with the only joints being above ground at the manifold making it easy to locate and repair.

Does my underfloor heating run all the time or can I turn it off?

Yes you will be able turn off individual rooms or the whole system if and when required depending on the number of thermostats you have.

What is the difference between heating zones and a number of different pipe loops in the same room?

A heating zone is the area that the thermostat controls. So where there is a large room having a 3 port manifold and 1 thermostat that is only a single zone system although with teh addition of multiple thermostats if your rooms were small it could be a three zone system. Generally more number of ports on a manifold dictate the number of zones your system is capable of. All of our kits come with one thermostat even though they are capable of more than one zone.

With the pipe being either in the floor or under floor boards will it take a long time to heat up?

No, this won’t be a problem. By using the right controls you will have a comfort and economy mode and can eliminate any delay, however, buildings with high heat loss or draughts could take longer; with some of our highly efficient systems it can offer a response